| | Safety tests |
|
Visual testing |
- Review of the casing/enclosure regarding risk of fire and mechanical hazards.
- Examination of clearance and creepage distances (including disassembly of the power supply, check of the tracing and the position of components in primary and secondary position).
- Protective earth connection.
- Markings.
|
|
Electrical / climatic testing |  |
| (up to 500 V / 44-66 Hz / 75 A) |
- Protective earth.
- Electric strength.
- Leakage current.
- Abnormal operating and fault conditions.
|
|
Mechanical testing |  |
- Enclosure openings (access to hazardous voltages).
- Mechanical strength and stress relief (using the steel ball, steady force and tilt tests).
|
|
Preparing test reports |
- Check available certificates and test reports.
- Prepare test report for CE marking or international use (CB test report).
|
 |  |  |  |